Responses
Define the Responses
Define the maximum percent thinkness reduction
- Select the Responses panel.
- From the possible response types select: D3PLOT.
- For Parts to be included choose All Parts.
- For Result Type select Misc.
- For Component select %_thickness_reduction.
- And select the Maximum Value.
- And the maximum value should be taken from time 0 to the current time.
- For Response Name enter prc_thick_red_max.
- Push the Add button.
Define the FLD
- From the possible response types select: FLD.
- For Parts to be included choose List of Parts.
- In the List of Parts enter 1.
- Push the (Add) > button.
Repeat the previous steps and create this list of parts:
List of Parts: |
---|
1 |
2 |
3 |
- For Sampling locatin select Center surface.
- For Load curve ID enter 90.
- For Response Name enter PLD.
- Push the Add button.
Define the minimum shell thickness
- From the possible response types select: D3PLOT.
- For Parts to be included choose List of Parts.
- In the List of Parts enter 1.
- For Result Type select Misc.
- For Component select shell_thickness.
- And select the Minimum Value.
- And the minimum value should be taken from time 0 to the current time.
- For Response Name enter thick_min.
- Push the Add button.